• JNIOSH-TR-46-2
• JNIOSH-TR-46-6
E4
Certificate: CML17JPN1145X
Ex d [ia] IIC T6...T1 Ga/Gb (integral transmitter and sensor)
Ex d [ia Ga] IIC T6 Gb (remote transmitter)
Ex ia IIC T6...T1 Ga (remote sensor)
Ambient temperature range: -20 °C to +60 °C
Process temperature range: -202 °C to +427 °C
Ambient temperature
(°C)
Process temperature
(°C)
T-Class sensor (°C)
–50 to +70 –200 to +75 T6
–50 to +70 –200 to +95 T5
–50 to +70 –200 to +130 T4
–50 to +70 –200 to +195 T3
–50 to +70 –200 to +290 T2
–50 to +70 –200 to +427 T1
42 VDC Max, 4-20 mA HART
32 VDC Max, Fieldbus
U
m
= 250V
Special conditions for safe use (X):
1. For information regarding the dimensions of the flameproof
joints, the manufacturer shall be contacted.
2. The Flowmeter shall be provided with special fasteners of
property class A2-70 or A4-70.
3. Units marked with “Warning: Electrostatic Charging Hazard”
may use non-conductive paint thicker that 0.2mm. Precaution
shall be taken to avoid ignition due to electrostatic charge on the
enclosure.
9.6
Brazilian certifications (INMETRO)
I. S. certification
• ABNT NBR IEC 60079-0: 2013
• ABNT NBR IEC 60079-11: 2013
• Portaria INMETRO no. 179: 18 May 2010
I2
Certification Number: DNV 18.0003 X