JNIOSH-TR-46-2
JNIOSH-TR-46-6
E4
Certificate: CML17JPN1145X
Ex d [ia] IIC T6...T1 Ga/Gb (integral transmitter and sensor)
Ex d [ia Ga] IIC T6 Gb (remote transmitter)
Ex ia IIC T6...T1 Ga (remote sensor)
Ambient temperature range: -20 °C to +60 °C
Process temperature range: -202 °C to +427 °C
Ambient temperature
(°C)
Process temperature
(°C)
T-Class sensor (°C)
–50 to +70 –200 to +75 T6
–50 to +70 –200 to +95 T5
–50 to +70 –200 to +130 T4
–50 to +70 –200 to +195 T3
–50 to +70 –200 to +290 T2
–50 to +70 –200 to +427 T1
42 VDC Max, 4-20 mA HART
32 VDC Max, Fieldbus
U
m
= 250V
Special conditions for safe use (X):
1. For information regarding the dimensions of the flameproof
joints, the manufacturer shall be contacted.
2. The Flowmeter shall be provided with special fasteners of
property class A2-70 or A4-70.
3. Units marked with “Warning: Electrostatic Charging Hazard”
may use non-conductive paint thicker that 0.2mm. Precaution
shall be taken to avoid ignition due to electrostatic charge on the
enclosure.
9.6
Brazilian certifications (INMETRO)
I. S. certification
ABNT NBR IEC 60079-0: 2013
ABNT NBR IEC 60079-11: 2013
Portaria INMETRO no. 179: 18 May 2010
I2
Certification Number: DNV 18.0003 X
Quick Start Guide October 2018
44 Rosemount
8800D Series Vortex Flowmeter

Other manuals for Emerson Rosemount 8800D Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Rosemount 8800D Series and is the answer not in the manual?

Emerson Rosemount 8800D Series Specifications

General IconGeneral
BrandEmerson
ModelRosemount 8800D Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals