9.5 USA
9.5.1 USA Explosion-proof
Certificate:
SGSNA/24/SUW/00028X
Standard:
UL 1203, 6th Ed., Rev 2023
Marking:
XP CL I, DIV 1, GP CD, T4 (ST) and XP CL I, DIV 1, GP CD,
T2 (HT) (–40 °C ≤ T
a
≤ +75 °C)
Specific conditions of use:
1. Product must be installed per NEC 70 Section 501 for
hazardous locations.
2. Product not intended for connection with rigid metallic
conduits as it was not tested for that configuration.
9.6 Canada
9.6.1 Canada Explosion-proof
Certificate:
SGSNA/24/SUW/00028X
Standard:
CSA C22.2 No. 30:20, 4th Ed., April 2020 Rev: March
2023
Marking:
XP CL I, DIV 1, GP CD, T4 (ST) and XP CL I, DIV 1, GP CD,
T2 (HT) (–40 °C ≤ T
a
≤ +75 °C)
Specific conditions of use:
1. Product must be installed per NEC 70 Section 501 for
hazardous locations.
2. Product not intended for connection with rigid metallic
conduits as it was not tested for that configuration.
9.7
Europe
9.7.1 ATEX Flameproof
Certificate:
SGS23ATEX0042X
Standard:
EN IEC 60079-0: 2018 and EN 60079-1: 2014
Marking:
II 2 G, Ex db IIB T6…T4 Gb (ST) and II 2 G, Ex db IIB
T6…T2 Gb (HT) (–40 °C ≤ T
a
≤ +75 °C)