Maximum of 40 mW (16 dBm) EIRP for WN2 High Gain option
A.1.5 Environmental
Operating temperature range
–40 to 158 °F (–40 to 70 °C)
Operating humidity range
10–90 percent relative humidity
A.1.6 EMC performance
Meets all industrial environment requirements of EN61326 and NAMUR NE-21. Maximum
deviation <1% span during EMC disturbance.
Note
During surge event, device may exceed maximum EMC deviation limit or reset; however,
device will self-recover and return to normal operation within specified start-up time.
A.1.7
Antenna options
Integrated Omni-directional Antenna Optional remote mount Omni-directional Antenna
A.2 Physical specifications
A.2.1 Weight
10 lb. (4.54 kg)
A.2.2
Material of construction
Housing
Low-copper aluminum, NEMA
®
4X
Paint
Polyurethane
Cover gasket
Silicone Rubber
Antenna
Integrated Antenna: PBT/PC
Remote Antenna: Fiber Glass
Specifications and Reference Data Reference Manual
September 2020 00809-0200-4420
66 Emerson.com/Rosemount