EasyManua.ls Logo

Empire AXE - NXL Style Full Auto Mode; Max Rate of Fire (ROF); Dwell Setting; Trigger De-Bounce

Empire AXE
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
parameters are achieved. The default setting meets 2011 Millennium marker rules.
Default: Max ROF = 10.0bps; Ramp Start = 3shots; Ramp Sustain = 6tps(trigger
pulls per second)
NXL Style Full Auto: Marker will shoot in semi-auto mode equal to the number of
shots specified by the Ramp Start setting, then will go into full automatic mode as long
as the trigger is held down. If the marker is not fired for 1 second the marker will then
shoot semi-auto again until Ramp Start is achieved again
Default: Max ROF=12.0bps; Ramp Start = 3shots
MAX RATE OF FIRE (ROF)
-WILL BE INDICATED BY SOLID GREEN LED
This setting controls the maximum number of paintball per second the marker is al-
lowed to fire. The setting can be varied from 8 to 20 balls per second (bps) in 0.5bps
intervals. Use the chart below to set the Max ROF.
Default: Max ROF = 15.0 bps
You must be in the Settings Mode to change the Max ROF, see above for instructions
on how to enter Settings Mode. After choosing Max ROF Mode (Solid Green), hold
the Trigger to get into the Mode, the LED will flash Red LED blinks equal to the current
setting, followed by a pause. Pull the trigger the number of times equal to your new
desired setting (see chart below). Once done, the LED will cycle through an array of
colors to indicate the setting is saved and return to the Settings Mode.
Example: 10 LED blinks = 12.5 BPS
# of Blinks BPS value # of Blinks BPS value # of Blinks BPS value
1 8.0 10 12.5 18 16.5
2 8.5 11 13.0 19 17.0
3 9.0 12 13.5 20 17.5
4 9.5 13 14.0 21 18.0
5 10.0 14 14.5 22 18.5
6 10.5 15 15.0 23 19.0
7 11.0 16 15.5 24 19.5
8 11.5 17 16.0 25 20.0
9 12.0
DWELL SETTING
- WILL BE INDICATED BY SOLID AMBER LED
This setting controls the amount of time the solenoid valve is left open. A setting too
high will waste excess gas and affect efficiency. A setting too low will prevent marker
from operating properly. It is not recommended to change this setting unless you are
an experienced user. Minimum dwell time is 3.0ms and is increased in .5ms incre-
ments up to 10ms. Use the chart below to set the Dwell.
Default: Dwell = 8.0 ms
You must be in the Settings Mode to change the Dwell Setting, see above for instruc-
tions on how to enter Settings Mode. After choosing Dwell Setting (Solid Amber),
hold the Trigger to get into the Mode, the LED will flash Amber
LED blinks equal to the current setting, followed by a pause. Pull the trigger the num-
ber of times equal to your new desired setting (see chart below). Once done, the LED
will cycle through an array of colors to indicate the setting is saved and return to the
Settings Mode.
# of Blinks Dwell in ms # of Blinks Dwell in ms
1 3.0 8 6.5
2 3.5 9 7.0
3 4.0 10 7.5
4 4.5 11 8.0
5 5.0 12 8.5
6 5.5 13 9.0
7 6.0 14 9.5
8 6.5 15 10.0
TRIGGER DE-BOUNCE
- WILL BE INDICATED BY A FLASHING RED LED
Time in milliseconds the trigger pull must be released before the next trigger pull can
be registered. This eliminates electronic noise and vibrations (“Trigger Bounce”) that
the board may wrongly interpret as a trigger action (trigger pull) and fire the marker. A
higher setting will reduce the bounce. A lower setting will allow for more bounce. One
blink corresponds to 1ms of De-Bounce time. De-Bounce is adjustable from 1-15ms
in 1.0ms increments.
Default: De-Bounce = 5.0 ms

Related product manuals