VERSION
DOCUMENT TITLE
RELEASE DATE
00
EL 4.0 Owner’s Manual
2022-09-12
EL Owner’s Manual – Rev.00 September 2022 3
Restriction of hazardous substances directive RoHS II
2011/65/EU, delegate directive UE 2015/863 and directive
2017/2102
Noise level at 1 m
<85 dB
Ventilation and Safety
Recommendation
To be installed in a safe (non hazardous) area only.
Indoor: Ventilation depends on room size, Hydrogen detection
system with a safety circuit is recommended
Outdoor: Protect from outside environmental influences, if
integrated into a cabinet. Ensure the safety concept of each
integrated module is respected.
Environmental
Operating Conditions
5 °C to 45 °C, up to 90% humidity, non-condensing
1
5 °C to 50 °C, up to 90 % humidity, non-condensing
2
Storage Conditions
2 °C to 55 °C, up to 90 % humidity, non-condensing
IP Rating
IP 20
Interfaces
H
2
Outlet
¼” bspp female port
O
2
Vent Outlet
bspp female port
H
2
Vent Outlet
¼” bspp female port
H
2
O Inlet
10 mm push-fit female bulkhead connector
Fill / Drain Port
10 mm CPC quick connector
Cooling Water Inlet
2
10 mm push-fit female bulkhead connector
Cooling Water Outlet
2
10 mm push-fit female bulkhead connector
1
Air Cooled electrolysers only (Liquid cooled versions excluded)
2
Liquid Cooled electrolysers only (Air cooled versions excluded)