Watkins Manufacturing Corporation
Vista, California
USA
This manual contains installation, operating, maintenance, and service information
for the following ENDLESS POOLS
fitness systems:
305036.17 B (3/17)
FITNESS SYSTEM SPECIFICATIONS
©
2017 WATKINS MANUFACTURING CORPORATION.
ENDLESS POOLS is a trademark of WATKINS MANUFACTURING CORPORATION, registered in the U.S., Canada, CTM and other countries.
E2000-58
610 cm
x
226 cm
147 cm 18 m² 5 m² 3,000 3,000
7,740
liters
1,325
liters
1,855
kg
11,720
kg
980
kg/m²
Single Phase Model
220-240 volt, 50Hz,
48 amp Single phase
GFCI protected circuit
or
Three Phase Model
380-415V, 3N~, 24A,
50Hz,
Three phase
24 amp/phase
GFCI protected circuit
E2000-58
Treadmill**
610 cm
x
226 cm
147 cm 18 m² 5 m² 3,000 3,000
7,575
liters
1,325
liters
1,905
kg
11,605
kg
970
kg/m²
Single Phase Model
220-240 volt, 50Hz,
48 amp Single phase
GFCI protected circuit
or
Three Phase Model
380-415V, 3N~, 24A,
50Hz,
Three phase
24 amp/phase
GFCI protected circuit
Footprint
dimensions
Swim side effective
filter area
Height
Swim side heater
(Watts)
Dead weight
Dry weight
Spa side effective
filter area
Swim side water
capacity
Spa side heater
(Watts)
Spa side water
capacity
Filled weight*
Electrical
requirements
CAUTION: Watkins Manufacturing Corporation suggests a structural engineer or contractor be consulted before the fitness system is placed on an elevated deck.
* NOTE: The “Filled weight” and “Dead weight” of the fitness system includes the weight of 10 occupants (assuming an average occupant weight of 80 kg).
**NOTE: Single Phase 48 amp model: swim side heater will stop heating during tandem (treadmill/swim machine) use due to circuit saver protection. Spa side
heater and one jet pump will operate simultaneous, should the second jet pump be turned on the spa side heater will stop heating until a jet pump is turned off.
Converting the Single phase model from 48 amp to a 72 amp system will allow both spa jet pumps and heater to operate simultaneously on spa side.
Three Phase Model, swim side heater will stop heating during tandem (treadmill/swim machine) use due to circuit saver protection. Spa side heater and both jet
pumps will operate simultaneously.
Ask your ENDLESS POOLS dealer for more information.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Endless Pools E2000 and is the answer not in the manual?

Endless Pools E2000 Specifications

General IconGeneral
BrandEndless Pools
ModelE2000
CategoryFitness Equipment
LanguageEnglish

Related product manuals