Operating Manual
TOPwave
Microwave System for Pressure Digestion

Table of Contents

Questions and Answers

  • B
    Brandon BirdAug 20, 2025
    Why does the oven chamber get very hot in Endress+Hauser Analytik Jena TOPwave?
    • K
      kscottAug 20, 2025
      If the oven chamber of your Endress+Hauser Laboratory Equipment gets very hot, especially the rotor, it could be due to a low acid volume. To resolve this, increase the quantity of fluid, referring to the 'Operation' section for the minimum filling quantity. Alternatively, reduce the total running time to a maximum of 30 minutes.
  • M
    Marissa VillaAug 22, 2025
    What to do if spark formation occurs in the oven of Endress+Hauser Laboratory Equipment?
    • A
      audrey41Aug 22, 2025
      If spark formation occurs in the oven of your Endress+Hauser Laboratory Equipment, it could be due to a low acid volume. Increase the quantity of fluid, referring to the 'Operation' section for the minimum filling quantity. Alternatively, the rupture disc may be corroded or damaged, in which case you should exchange the burst disk.
  • C
    Connie RogersAug 25, 2025
    Why does the rupture disc trigger frequently in Endress+Hauser Analytik Jena TOPwave Laboratory Equipment?
    • N
      noahperezAug 25, 2025
      If the rupture disc triggers frequently in your Endress+Hauser Laboratory Equipment, replace the rupture disc more frequently. Also, check the turntable function. Reduce the weighing-in quantity and the maximum temperature. Contact Service if the temperature measurement is defective.
  • D
    Dylan JordanAug 26, 2025
    How to fix swivel lid that cannot be opened on Endress+Hauser Laboratory Equipment?
    • J
      Jeremy PattersonAug 26, 2025
      If the swivel lid of your Endress+Hauser Laboratory Equipment cannot be opened, check the mains cable or connector cable to the Auto Controller to ensure it is not loose. Also, ensure the mains switch is switched on.
  • N
    Nicholas JohnsonAug 28, 2025
    What to do if gas fumes escape from Endress+Hauser Analytik Jena TOPwave?
    • S
      Steven PerezAug 28, 2025
      If gas fumes or gas odor escapes from your Endress+Hauser Laboratory Equipment, the vessels may be leaking. Try to dilate the lip seal of the locking lid more. If it is damaged, replace it, referring to the 'Operation' section.
  • L
    Laura ThompsonAug 29, 2025
    What causes vessels to leak in Endress+Hauser Analytik Jena TOPwave?
    • D
      davisjasonAug 29, 2025
      If the vessels leak in your Endress+Hauser Laboratory Equipment, the locking lid may not be firmly enough in place on the digestion vessel. Dilate the lip seal of the locking lid more; if damaged, replace it, referring to the 'Operation' section.
  • A
    Angela WintersAug 31, 2025
    What does 'Turntable Error' mean on Endress+Hauser Analytik Jena TOPwave?
    • K
      Kayla MasonAug 31, 2025
      If the program stops during the start phase with a 'Turntable Error' on your Endress+Hauser Laboratory Equipment, ensure the vessels are put in correctly. Contact Service if the decoder or motor is defective.
  • M
    Mallory ObrienSep 2, 2025
    Why does the swivel lid jam while closing on Endress+Hauser Laboratory Equipment?
    • M
      Michael FergusonSep 2, 2025
      If the swivel lid jams while closing on your Endress+Hauser Laboratory Equipment, the turntable may not be correctly engaged in the drive axis. Position the turntable correctly.
  • T
    thomasamandaSep 4, 2025
    Why does the RCCB switch trigger often with Endress+Hauser Analytik Jena TOPwave Laboratory Equipment?
    • J
      Jessica HendersonSep 4, 2025
      If the RCCB switch of the supply line triggers often with your Endress+Hauser Laboratory Equipment, Contact Service because the magnetron is defective or there is a short circuit in the device.
  • R
    Robert RhodesSep 6, 2025
    What to do if magnetron switches off during digestion in Endress+Hauser Analytik Jena TOPwave?
    • B
      brownbrittanySep 6, 2025
      If the magnetron switches off during digestion with your Endress+Hauser Laboratory Equipment, contact Service because the magnetron overheated, there is too little fluid, the oven was operated empty, or the pressure or temperature difference is set too low.

Summary

Basic Information

User Manual Notes

Explains the purpose, conventions, and signal word meanings of the user manual.

Intended Use

Details the specific applications and limitations of the TOPwave microwave digestion system.

Warranty and Liability

Outlines the terms and conditions of the product warranty and manufacturer liability.

Safety Instructions

General Safety Notes and Unit Markings

Covers general safety guidelines, warning symbols, and labels on the unit.

Qualified Users

Specifies the required qualifications and training for operating personnel.

Transport and Commissioning Safety

Provides safety precautions for moving and setting up the equipment.

General Safety Information

Highlights crucial safety precautions for microwave digestion procedures and handling vessels.

Safety Equipment and Emergency Procedures

Details essential safety equipment and actions in case of emergencies.

Installation and Setup

Ambient Conditions

Specifies the environmental requirements for system installation and operation.

Device Description

Basic Unit Overview

Describes the main components and features of the TOPwave microwave system.

Temperature Control System

Explains how the system monitors and regulates sample temperatures.

Pressure Monitoring System

Details the optional system for measuring and controlling internal vessel pressure.

Pressure Vessels and Rotor System

Describes the different types of pressure vessels and their rotor configurations.

Installation and Setup

Unpacking the System

Provides instructions for safely removing and inspecting the equipment from packaging.

Installing the TOPwave System

Guides the user through the physical setup and connection of the microwave.

Selecting Setup Parameters

Details how to configure system settings and parameters via the control unit.

Operating the TOPwave

Setup Methods and General Notes

Explains basic operating principles, sample heating, and pressure management.

Control Unit Operation

Describes how to interact with the touch-screen control interface and its functions.

Selecting and Modifying Applications

Guides users on choosing, customizing, and saving digestion programs.

Developing New Applications

Outlines a systematic procedure for creating and optimizing new digestion methods.

Performing a Digestion Procedure

Provides step-by-step instructions for running a digestion process.

Sample Loading Procedures

Details the correct methods for loading different types of pressure vessels.

Handling PM 40, PM 60, PL 100 Vessels

Specific instructions for loading and preparing PM 40, PM 60, and PL 100 pressure vessels.

Handling QX 20;QX 22 Vessels

Specific instructions for loading and preparing QX 20/QX 22 pressure vessels.

Handling CX 100 Vessels

Specific instructions for loading and preparing CX 100 pressure vessels.

Sample Removal and Cooling

Instructions for safely removing and cooling digested samples from the oven.

Digestion Reports and Data Display

How to access, view, and interpret recorded digestion data and reports.

Data Export via USB

Procedure for transferring saved digestion data to a USB storage device.

Evaporating Unit Operation

Instructions for using the optional evaporating unit for sample concentration.

Evaporating Unit Installation & Commissioning

Steps for setting up and preparing the optional evaporating unit.

Evaporating Unit Operating Procedures

Guidance on operating the evaporating unit after installation.

PC Control and Network Setup

Instructions for connecting and controlling the TOPwave via a PC.

PC Control Safety Information

Safety precautions related to using the PC control software.

PC Security Settings

Steps for configuring browser security settings for PC control.

PC Control via Web Visualization

How to access and use the system's web-based control interface.

Data Transfer Methods

Procedures for transferring data using FTP and web visualization.

Care and Maintenance

General Safety Information for Care

Safety precautions to observe during cleaning and maintenance operations.

Cleaning Procedures

Detailed instructions for cleaning different parts of the TOPwave system.

Oven Chamber Cleaning

Specific guidance on cleaning the microwave oven chamber.

Control Unit and Gas System Cleaning

How to clean the control unit and gas collection system.

Vessel Cleaning Methods

Procedures for cleaning digestion vessels after use.

Cap for Pressure Control Cleaning

Instructions for cleaning the pressure control cap components.

Maintenance Procedures

Aligning Pressure Measurement

Steps for calibrating the pressure measurement system using pure water.

Output Power Measurement

Procedure to check and verify the magnetron's output power.

Troubleshooting Common Issues

Provides solutions for common faults encountered with the microwave device and control unit.

Fuse Replacement Guide

Instructions on how to safely replace the unit's fuses.

Information on Disposal

Proper Disposal Guidelines

Information on how to dispose of the TOPwave and its components responsibly.

Specifications

Technical Data of the System

Lists detailed technical specifications for the microwave oven and control unit.

Pressure Vessel Specifications

Details specifications for different types of pressure vessels, including volume and limits.

Guidelines and Standards Compliance

Outlines the standards and directives the TOPwave complies with.

Appendix

Tips and Tricks for Operation

Provides helpful advice and techniques for optimizing TOPwave usage.

Small Sample Quantity Handling

Guidance on digesting very small sample amounts efficiently.

Multiple Samples per Vessel

Tips for increasing sample throughput by processing multiple samples in one vessel.

Higher Sample Throughput Techniques

Methods to maximize sample processing speed and efficiency.

Cooling Down Samples Safely

Recommended procedures for cooling digested samples after the process.

Rupture Discs and Locking Lids

Information on rupture discs, locking lids, and their maintenance.

Weighing Cup Usage

Instructions on using weighing cups for sample preparation.

Available Applications

Information on obtaining and using various pre-defined applications.

Vessel Positioning in Rotors

Illustrates the optimal placement of vessels within the turntable rotors.

Unit Conversation

Provides conversion factors for common units used in the manual.

Abbreviation Glossary

Defines common abbreviations and acronyms used in the documentation.

Endress+Hauser Analytik Jena TOPwave Specifications

General IconGeneral
BrandEndress+Hauser
ModelAnalytik Jena TOPwave
CategoryLaboratory Equipment
LanguageEnglish