Deltapilot M 4...20 mA HART Operation
Endress+Hauser 27
Operator Display/operat. Contains parameters that are needed to configure the measured value
display (selecting the values displayed, display format, display contrast,
etc.).
With this submenu, users can change the measured value display
without affecting the actual measurement.
Service
engineer/technician
Setup Contains all the parameters that are needed to commission measuring
operations. This submenu has the following structure:
Standard setup parameters
A wide range of parameters, which can be used to configure a typical
application, is available at the start. The measuring mode selected
determines which parameters are available.
After making settings for all these parameters, the measuring
operation should be completely configured in the majority of cases.
"Extended setup" submenu
The "Setup" submenu contains additional parameters for more
in-depth configuration of the measurement operation to convert the
measured value and to scale the output signal.
This menu is split into additional submenus depending on the
measuring mode selected.
Service
engineer/technician
Diagnosis Contains all the parameters that are needed to detect and analyze
operating errors. This submenu has the following structure:
Diagnostic list
Contains up to 10 error messages currently pending.
Event logbook
Contains the last 10 error messages (no longer pending).
Instrument info
Contains information on the device identification.
Measured values
Contains all the current measured values
Simulation
Is used to simulate pressure, level, current and alarm/warning.
Reset
Expert Expert Contains all the parameters of the device (including those in one of the
submenus). The "Expert" submenu is structured by the function blocks of
the device. It thus contains the following submenus:
System
Contains all the device parameters that neither affect measurement
nor integration into a distributed control system.
Measurement
Contains all the parameters for configuring the measurement.
Output
Contains all the parameters for configuring the current output.
Communication
Contains all the parameters for configuring the HART interface.
Application
Contains all the parameters for configuring the functions that go
beyond the actual measurement (e.g. totalizer).
Diagnosis
Contains all the parameters that are needed to detect and analyze
operating errors.
User role Submenu Meaning/use