Cerabar S/Deltabar S/Deltapilot S FOUNDATION Fieldbus Parameter description (FF configuration program)
Endress+Hauser 73
Height Unit Level Easy/
HEIGHT_UNIT_EASY
Index: 84
Data type: UNSIGNED16
Access: OOS
Select the height unit. The measured pressure is converted to the chosen height unit using
the Density Unit Level Easy/DENSITY_UNIT_EASY and Adjust Density Level Easy/
ADJUST_DENSITY_EASY parameters.
Options:
•mm
•cm
•dm
•m
•inch
•ft
Factory setting:
m
Output Unit Level Easy/
OUTPUT_UNIT_EASY
Index: 85
Data type: UNSIGNED16
Access: auto
Select the unit for the measured value display and the MEASURED VALUE parameter
( ä 200).
!
Note!
The selected unit is used only to describe the measured value. This means that when
selecting a new output unit, the measured value is not converted.
Example:
Current measured value: 0.3 ft
New output unit: m
New measured value: 0.3 m (9.8 ft)
Options:
•%
mm, cm, dm, m
•ft, inch
cm³, dm³, m³, m³E³
•l, hl
•ft³, ft³E³
gal, bbl, lgal
•g, kg, t
lb, ton, oz
Factory setting:
%
Calibration Mode Level
Easy/
CALIBRATION_MODE_
EASY
Index: 86
Data type: UNSIGNED8
Access: OOS
Select the calibration mode.
Options:
•Wet
Wet calibration takes place by filling and emptying the container. In the case of two
different levels, the level, volume, mass or percentage value entered is assigned to the
pressure measured at this point in time. ( See also this table, parameter descriptions for
Empty Calib. Level Easy/EMPTY_CALIBRATION_EASY and Full Calib. Level Easy/
FULL_CALIBRATION_EASY)
•Dry
Dry calibration is a theoretical calibration. For this calibration, you specify two pressure-
level value pairs via the following parameters: Empty Calib. Level Easy/
EMPTY_CALIBRATION_EASY, Empty Pressure Level Easy/EMPTY_PRESSURE_EASY,
Full Calib. Level Easy/FULL_CALIBRATION_EASY and Full Pressure Level Easy/
FULL_PRESSURE_EASY.
Factory setting:
Wet
Density Unit Level Easy/
DENSITY_UNIT_EASY
Index: 87
Data type: UNSIGNED16
Access: OOS
Select the density unit. The measured pressure is converted to a height using the Height Unit
Level Easy/HEIGHT_UNIT_EASY, Density Unit Level Easy/DENSITY_UNIT_EASY and
Adjust Density Level Easy/ADJUST_DENSITY_EASY parameters.
Options:
•g/cm
3
•kg/dm
3
•kg/m
3
US lb/in
3
US lb/ft
3
Factory setting:
kg/dm³