Mounting Flowphant T DTT31, DTT35
10 Endress+Hauser
4.1.3 General installation instructions
NOTICE
Damage to the device.
To ensure correct monitoring, the sensor must be installed in a way that produces a fully
developed flow profile.
Stabilization sections (5x DN) must be provided in the pipe downstream from a pump, pipe
elbows, internal fixtures and cross-sectional changes.
NOTICE
Damage to the device.
Do not turn the device into the process connection thread at the housing→  10.
Always install the device at the wrench flats.
Use a suitable open-ended wrench →  10.
The local display can be rotated electronically by 180 °→  17.
The top housing section can be rotated mechanically by up to 310 °.