Endress+Hauser Flowphant T DTT31 Technical Information

Endress+Hauser Flowphant T DTT31
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TI00125R/09/en
71009492
Technical information
Flow switch
Flowphant
®
T DTT31, DTT35
Flow switch for safe monitoring of mass flow and temperature in
industrial processes
Application
Flow switch for monitoring and displaying relative mass flow
rates of liquid media in the range from
0.03 to 3 m/s (0.1 to 9.84 ft/s):
Flowphant
®
T DTT31
with thread connections or coupling
Flowphant
®
T DTT35
with process connections for hygienic applications
Application examples:
Monitoring cooling water circulation systems of pumps,
turbines, compressors and heat exchangers
Monitoring pump functionality
Leak monitoring in process lines
Monitoring lubrication systems
Filter monitoring in the beverage industry
Benefits at a glance
This compact flow switch impresses with the latest in
technology being used:
Practically no pressure loss
Configuration software ReadWin
®
2000 or FieldCare for
quick configuration and reliable storage of device settings
Optional: 4 to 20 mA analog output to read out the flow rate
as percentage value
Optional: second switch output or 4 to 20 mA analog output
for temperature monitoring
Function check and process information onsite thanks to
digital display at device
Top housing section which can be rotated 310° and rotatable
display make it possible to read the measured values in all
orientations
DTT35: 3-A marked

Other manuals for Endress+Hauser Flowphant T DTT31

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Endress+Hauser Flowphant T DTT31 and is the answer not in the manual?

Endress+Hauser Flowphant T DTT31 Specifications

General IconGeneral
Device TypeFlow Switch
Process Temperature-40°C to +150°C
Process PressureMax. 40 bar
Output SignalPNP/NPN
ConnectionM12 connector, terminal box
Supply Voltage10 to 30 V DC
Process ConnectionG 1/2, G 1, 1/2" NPT, 1" NPT
Response Time< 1 second
Protection RatingIP67
Operating Temperature-40 to +60 °C