EasyManua.ls Logo

Endress+Hauser Flowphant T DTT31 - Human Interface; Operating Elements; Onsite Operation

Endress+Hauser Flowphant T DTT31
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DTT31, DTT35
12 Endress+Hauser
Display: Polycarbonate PC-FR (Lexan
®
)
Seal between display and housing: SEBS THERMOPLAST K
®
Keys: Polycarbonate PC-FR (Lexan
®
)
Human interface
Operating elements Position of display and operating elements
T09-TTR31xxx-19-xx-xx-en-001
Onsite operation Menu-guided operation using operating keys.
Function group Function (display) Description
BASE
(basic functions)
Display (DISP) Display assignment:
OFF
Display of current measured value or of configured
switch point (switch 1)
Display of current measured value or of configured
switch point (switch 1) rotated 180°
Display of current medium temperature
Display of current medium temperature rotated 180°
Factory setting: current measured value
UNIT Display medium temperature unit °C or °F
Factory setting: °C
!
Note!
Only visible if the current medium temperature is selected
in the DISP mode.
Damping (TAU) Measured value damping with regard to display value and
output:
0 (no damping) or 9 to 40 s (in increments of 1 second)
Factory setting: 0 s
DESINA (DESI)
Only for 2 x PNP switch outputs
Behavior as per DESINA: The PIN of the M12 connector
is assigned in accordance with the guidelines of DESINA.
(DESINA = DistributEd and Standardized INstAllation
technology for machine tools and manufacturing systems)
CAL (calibration) Learn High Flow (HIF) Setting for maximum flowrate occurring.
100% value
Learn Low Flow (LOWF) Setting for minimum flowrate occurring.
0% value

Other manuals for Endress+Hauser Flowphant T DTT31