Operation TMT180
12 Endress+Hauser
5Operation
5.1 Communication
The head transmitter must be set up using a PC and configuration set. The following points must
be taken into account if trouble-free setup is to be achieved:
Configuration software installation
More details and download see:
www.readwin2000.com
Connect the head transmitter to the PC using the connection cable from the configuration set.
5.1.1 Configuration software installation (ReadWin
®
2000)
5.1.2 Connecting the head transmitter to the PC using the
configuration kit connection cable
"
Caution!
Please make sure that when setting up the device by means of the configuration kit (see chap.
accessories) that the supply to the programming device (=PC and interface cable) is galvanically
isolated from the transmitter power supply, e.g.:
By using a battery operated PC (e.g. laptop) when the transmitter is already installed on plant
By setting up without any wiring of the power supply to the transmitter
1. Connect the SETUP connector of the interface connecting cable to the SETUP socket in the
head transmitter (see ’Fig. 7’ in Chapter 4.2).
2. Connect the RS232C connector to a free serial interface socket or the USB connector to a free
USB port on the PC. In order to achieve optimum connection, tighten the RS232C connector
screws to the PC.
!
Note!
When the PC serial interface cable is connected (see chapter ’Accessories’), the technical
specifications (e.g. measured error) are not observed. For this reason, during operation disconnect
the connection via the serial interface cable between the head transmitter and PC.
System conditions IBM PC or compatible computer (min. Pentium 166 MHz)
Windows 95/98/ME/NT4.0/2000/XP
64 MB RAM
–Mouse
–CD-ROM drive
Screen resolution 800 x 600 Pixel
free serial interface
Recommended minimum
configuration
Pentium 400 MHz
128 MB main RAM
120 MB free hard drive memory
Screen resolution 1024 x 768 Pixel
Installation start Start Windows
®
:
1. Place installations-CD in the respective drive
2. Generally, the ’Autorun’-file starts. If not, start “Setup.exe ”and follow the installation
instructions
3. If required the help/operating manual can be printed out once the software has been
successfully installed.