Do you have a question about the Endress+Hauser iTEMP HART TMT162 and is the answer not in the manual?
| Type | Temperature Transmitter |
|---|---|
| Communication Protocol | HART |
| Communication Protocol Version | HART 7 |
| Input | RTD, Thermocouple, Resistance |
| Output | 4...20mA |
| Enclosure Rating | IP66 |
| Housing | Stainless Steel |
| Configuration | Via HART communication |
| Operating Temperature | -40 to 85 °C |
| Housing Material | Aluminum |
| Process Connection | Various options available |
Essential safety information for proper operation.
Guidance on installing the transmitter correctly.
Instructions for electrical connections and wiring practices.
Overview of the transmitter's display and controls.
Steps for setting up and initialising the device.
Specifies the intended application and limitations of the transmitter.
Covers essential procedures for safe installation and operation.
Details safety precautions during the unit's operation.
Procedure for returning the device for service or repair.
Explains the meaning of safety icons used in the manual.
Information on identifying the device, including its legend plate.
Lists the items included in the product package.
Lists trademarks associated with the product and its software.
A condensed guide for rapid installation of the transmitter.
Specifies environmental and site requirements for installation.
Detailed procedures for mounting the transmitter, direct or remote.
Final checks to ensure the transmitter is installed correctly.
Simplified instructions for connecting the transmitter's wiring.
How to connect various types of temperature sensors.
Procedures for connecting the main transmitter unit and HART communication.
Guidelines for proper cable shielding and grounding.
Information on the transmitter's ingress protection ratings (NEMA 4X, IP67).
Verification steps after completing electrical connections.
Describes the transmitter's display indicators and icons.
How to operate and configure the device directly using its hardware.
Methods and procedures for communicating with the transmitter via HART.
Final checks before starting the commissioning process.
Steps to power up the transmitter after installation.
Streamlined process for configuring essential measurement parameters.
Detailed description of parameters for configuring the transmitter.
General guidance and checklists for fault finding.
Lists and explains error codes, causes, and remedies.
Troubleshooting for issues not accompanied by specific error codes.
Specifies sensor types, measuring ranges, and input parameters.
Details output signal, alarm behavior, load, and linearization.
Information on the digital filter settings.
Technical specifications for electrical isolation between circuits.
Required voltage range and power supply specifications.
Data on repeatability, response time, and accuracy.
Explains a method for sensor and transmitter matching.
Details the use of polynomials for RTD sensor linearization.