Levelflex FMP56, FMP57 FOUNDATION Fieldbus Mounting
Endress+Hauser 19
6.2 Mounting the device
6.2.1 Required mounting tools
For mounting thread 3/4": Hexagonal wrench 36 mm
For mounting thread 1-1/2": Hexagonal wrench 55 mm
To shorten rod or coax probes: Saw
To shorten rope probes:
Allen key AF 3 mm (for 4mm ropes) or AF 4 mm (for 6 mm ropes)
Saw or bolt cutter
For flanges and other process connections: appropriate mounting tools
To turn the housing: Hexagonal wrench 8 mm
6.2.2 Shortening the probe
Shortening rod probes
Rod probes must be shortened if the distance to the container floor or outlet cone is less than
10 mm (0.4 in). The rods of a rod probe are shortened by sawing at the bottom end.
Rod probes of FMP52 can not be shortened as they are coated.
Shortening rope probes
Rope probes must be shortened if the distance to the container floor or outlet cone is less than
150 mm (6 in).
B
A
C
A0021693