Mounting Levelflex FMP56, FMP57 FOUNDATION Fieldbus
26 Endress+Hauser
1. Unscrew the securing screw using an open-ended wrench.
2. Rotate the housing in the desired direction.
3. Tighten the securing screw (1.5 Nm for plastic housing; 2.5 Nm for aluminum or
stainless steel housing).
6.2.6 Turning the display
Opening cover
2.
1.
3 mm
A0021430
1. Loosen the screw of the securing clamp of the electronics compartment cover using an
Allen key (3 mm) and turn the clamp 90 ° counterclockwise.
2. Unscrew cover and check lid gasket, replace if necessary.
Turning the display module
1.
2.
A0036401
1. Pull out the display module with a gentle rotational movement.
2. Rotate the display module to the desired position: max. 8 × 45 ° in each direction.