EasyManua.ls Logo

Endress+Hauser Levelflex FMP57 - Page 149

Endress+Hauser Levelflex FMP57
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Levelflex FMP56, FMP57 FOUNDATION Fieldbus Operating menu
Endress+Hauser 149
Additional information Dependency on "Medium type" and "Medium group"
Medium type (→  148) Medium group Medium property
Solid Unknown
Liquid Water based (DC >= 4) DC 4 ... 7
Others Unknown
For dielectric constants (DC values) of many media commonly used in various
industries refer to:
the Endress+Hauser DC manual (CP01076F)
the Endress+Hauser "DC Values App" (available for Android and iOS)
For EOP level evaluation = Fix DC, the exact dielectric constant has to be entered
into the DC value parameter. Therefore, the Medium property parameter is not
available in this case.
Process property
Navigation  Setup → Advanced setup → Level → Process property
Description Specify typical rate of level change.
Selection For "Medium type" = "Liquid"
Very fast > 10 m (400 in)/min
Fast > 1 m (40 in)/min
Standard < 1 m (40in) /min
Medium < 10 cm (4in) /min
Slow < 1 cm (0.4in) /min
No filter / test
For "Medium type" = "Solid"
Very fast > 100 m (333 ft) /h
Fast > 10 m (33 ft) /h
Standard < 10 m (33 ft) /h
Medium < 1 m (3ft) /h
Slow < 0.1 m (0.3ft) /h
No filter / test
Factory setting Standard < 1 m (40in) /min
Additional information The device adjusts the signal evaluation filters and the damping of the output signal to the
typical rate of level change defined in this parameter:
For "Operating mode" = "Level" and "Medium type" = "Liquid"
Process property Step response time / s
Very fast > 10 m (400 in)/min 5
Fast > 1 m (40 in)/min 5
Standard < 1 m (40in) /min 14
Medium < 10 cm (4in) /min 39
Slow < 1 cm (0.4in) /min 76
No filter / test < 1

Table of Contents