Liquiphant FTL31 IO-Link Commissioning
Endress+Hauser 31
10.3 Function test with test magnet
L
WARNING
Risk of injury!
Ensure that no dangerous processes are triggered in the system.
To perform a function test, hold the test magnet against the marking on the nameplate (for at
least 2 seconds). This inverts the current switching status and the yellow LED changes state.
When the magnet is removed, the switch status valid at that time is adopted.
TEST
N
Ser. no.:
Order code:
Ext. ord. cd.:
A0020960
 14 Test magnet and marking
The test magnet is not included in the scope of delivery and can be ordered as an
optional accessory ,
A
→ "Accessories" section.
10.4 Commissioning with an operating menu
If an existing configuration is changed, measuring operation continues! The new or modified
entries are only accepted once the setting has been made.
Parameter changes are not accepted until after the parameters have been downloaded.
If using block configuration, parameter changes are accepted only after the parameters have
been downloaded.
L
WARNING
Risk of injury and damage to property due to uncontrolled activation of processes!
Make sure that downstream processes are not started unintentionally.