Appendix Liquisys M CLM223/253
118 Endress+Hauser
Function of R2 (7)
Switch off or on
Off
R271
Entry of alarm threshold
(switch-on point)
80 %
0.0 ... 100.0 %
R272
Pickup delay
entry
0
0 ... 2000 s
R274
On
Function of R2 (6)
Switch off or on
Off
R261
Entry of alarm threshold
(switch-on point)
80 %
0.0 ... 100.0 %
R262
Pickup delay
entry
0
0 ... 2000 s
R264
On
Function of R2 (5)
Switch off or on
Off; On
R251
Start pulse selection
int = internal
ext = external
i+ext = internal + external
i+stp = internal,
suppr. by ext
R252
Entry of pre-rinse time
20 s
0 ... 999 s
R253
Entry of cleaning time
10 s
0 ... 999 s
R254
Function of R2 (4)
Switch off or on
Off; On
R241
Rinse time setting
30 s
0 ... 999 s
R242
Pause time setting
360 min
1 ... 7200 min
R243
Set minimum
pause time
120 min
1...3600 min
R244
Function of R2 (3)
Switch off or on
Off; On; Basic; PID+B
R231
Entry of set point
0 µS/cm / 0 k ×cm /
0 %
entire meas. range
Ω
R232
Entry of
control gain Kp
1.00
0.01 ... 20.00
R233
Entry of integral action time
Tn (0.0 = no I component)
0.0 min
0.0 ... 999.9 min
R234
Function of R2 (2)
Switch off or on
Off; On
R221
Entry of switch-on
temperature
250.0
°C
35.0 ... +250.0 °C
R222
Entry of switch-off
temperature
250.0
°C
35.0 ... +250.0 °C
Pickup delay
setting
0 s
0 ... 2000 s
R224
R223
Function of R2 (1)
Switch off or on
Off; On
R211
Select contact
switch-on point
9999 mS/cm / 200 M ×cm /
9999 %
entire meas. range
Ω
R212
Select contact
switch-off point
9999 mS/cm / 200 M ×cm /
9999 %
entire meas. range
Ω
R213
Pickup delay
setting
0 s
0 ... 2000 s
R214
Limit contactor
configuration
USP
Clean
= Chemoclean
(only with rel. 3)
Timer
R2 (4)
R2 (5)
R2 (6)
EP PW
R2 (7)
PID controller
LC °C
= T limit contactor
LC PV
= cond. limit contactor
R2 (1)
R2 (2)
R2 (3)
Select contact to be
configured
Rel1; Rel2; Rel3; Rel4
R1
Entry of number of
table value pairs
1
1 ... 10
Table option selection
read
edit
T2
T1
Selection of table value
1
1 ... number of
table value pairs
asign
Entry of temperature
value (x value)
0.0
°C
35.0 ... +250.0 °C
T4
Entry of temperature
coefficient a (y value)
2.10 %/K
0.00 ... 20.00 %/K
Table status o.k.
yes; no
T5 T6
T3
Selection of table
to be edited
1
1 ... 4
K2
Selection of concentration
curve for calculation of
display value
Curve 1 ... 4
K1
Table option
selection
read
edit
K3
Set number of
value pairs
1
1 ... 10
K4
Select value pair
1
1 ... number of value pairs
in K4
K5
Entry of
uncompensated
conductivity value
0.0 µS/cm
0.0 ... 9999 mS/cm
K6
Language selection
ENG; GER
ITA; FRA
ESP; NEL
S1
Hold configuration
- none = no hold
- s+c = during setup
and calibration
- CAL = during calibration
- Setup = during setup
S2
Entry of
hold dwell period
10 s
0 ... 999 s
S4
Manual hold
off; on
S3
Entry of SW upgrade
release code
(plus package)
0000
0000 ... 9999
S5
Entry of SW upgrade
release code
Chemoclean
0000
0000 ... 9999
S6
Software
version
SW version
E141
Hardware
version
HW version
E142
Serial number
is displayed
Module name
is displayed
E143 E144
Software
version
SW version
E131
Hardware
version
HW version
E132
Serial number
is displayed
E133 E134
Module name
is displayed
Software
version
SW version
E121
Hardware
version
HW version
E122
Serial number
is displayed
E123 E124
Module name
is displayed
Software
version
SW version
E111
Hardware
version
HW version
E112
Serial number
is displayed
E113 E114
Module name
is displayed
Entry of address
HART: 0 ... 15
or Profibus 1 ... 126
I1
Tag description
@@@@@@@@
I2
Module selection
Relay
MainB
= mainboard
Contr = controller
E1 (1)
E1 (2)
E1 (3)
E1 (4)
Function group
INTERFACE
I
Function group
E + H SERVICE
E
R
Function group
RELAY
Function group
SERVICE
S
Function group
ALPHA TABLE
T
Function group
CONCENTRATION
K
A0027484-EN