BA00382P/00/EN/13.10
71123275
Valid from software version:
01.00.zz
Operating Instructions
Cerabar M PMC51, PMP51, PMP55
Deltabar M PMD55
Deltapilot M FMB50/51/52/53
Process pressure / Differential pressure, Flow / Hydrostatic
Deltapilot M
Deltabar M
Cerabar M

Table of Contents

Other manuals for Endress+Hauser Deltabar M PMD55

Questions and Answers:

Endress+Hauser Deltabar M PMD55 Specifications

General IconGeneral
BrandEndress+Hauser
ModelDeltabar M PMD55
CategoryTransmitter
LanguageEnglish

Summary

Safety instructions

Installation, commissioning and operation

Outlines requirements for safe installation, commissioning, and operation.

Operational and process safety

Emphasizes safety measures during device configuration and servicing.

Installation

Assembling and mounting the "separate housing" version

Steps for assembling and mounting the separate housing version.

PMP51, version prepared for diaphragm seal mount – welding recommendation

Recommendations for welding diaphragm seals onto PMP51.

Installing Deltabar M

Instructions for installing the Deltabar M differential pressure transmitter.

Installing Deltapilot M

Instructions for installing the Deltapilot M.

FMB50

Installation instructions for the FMB50 level transmitter.

FMB51/FMB52/FMB53

Installation notes for FMB51/52/53 models.

Installing Cerabar M

Instructions for installing the Cerabar M pressure transmitter.

Installation instructions for devices with diaphragm seals – PMP55

Specific installation guidance for PMP55 devices with diaphragm seals.

Wiring

Connecting the device

Step-by-step guide for electrical connection of the device.

Connecting the measuring unit

Information on supply voltage and cable specifications.

Connecting handheld terminal (DXR375/FC375)

How to connect a handheld terminal for setup and checking.

Operation

Operating options

Overview of different methods for operating the device.

Locking/unlocking operation

Procedures for locking and unlocking device operation using codes.

Operation with a device display (optional)

Details on using the optional local LCD display for operation.

Operation via HART handheld terminal

Using a HART terminal for parameter setup via menu.

Resetting to factory settings (reset)

How to reset device parameters to factory or order configuration.

Operation without operating menu

Describes operation using keys and DIP switches.

Function of the DIP switches

Explains the function of each DIP switch on the electronic insert.

Structure of the operating menu

Outlines the menu structure based on user roles and submenus.

Operation via FieldCare

Using FieldCare asset management tool for device configuration.

Operation with operating menu

Explains device operation via the menu system.

Commissioning

Function check

Pre-commissioning checks for installation and connection.

Commissioning without an operating menu

Steps for commissioning using keys without a display.

Level measuring mode

Functions for commissioning in level measuring mode.

Flow measuring mode (Deltabar M only)

Functions for commissioning in flow measuring mode for Deltabar M.

Commissioning with an operating menu

Procedures for commissioning using the device menu.

Position zero adjustment

Correcting pressure shifts due to device orientation.

Level measurement (Cerabar M and Deltapilot M)

Information and overview of level measurement methods.

"In pressure" level selection

Calibration without reference pressure for level measurement.

Calibration without reference pressure (dry calibration)

Further steps for dry calibration without reference pressure for height measurement.

"In height" level selection

Calibration without reference pressure for level measurement in height.

Calibration with partially-filled tank (wet calibration)

Wet calibration steps for a partially-filled tank.

Linearization

Manual entry of linearization tables for specific tank shapes.

Manual entry of the linearization table via the operating tool

Entering linearization data using FDT-based operating tools like FieldCare.

Semi-automatic entry of the linearization table

Semi-automatic method for entering linearization tables.

Pressure measurement

Procedures for calibrating pressure measurement.

Level selection "in pressure"

Calibration without reference pressure for level measurement.

Level selection "in height"

Calibration without reference pressure for level measurement in height.

Position adjustment

Correcting pressure shifts due to device orientation.

Pressure measuring mode

Functions for commissioning in pressure measuring mode.

Calibration with reference pressure (wet calibration)

Steps for wet calibration using reference pressure for height measurement.

Manual entry of the linearization table

Step-by-step guide for manually entering linearization data.

Adjustment of the Cerabar M/Deltapilot M on the high pressure side

Configuration steps for the high-pressure side.

Configuring measurement

Steps for configuring pressure, level, and flow measurements.

Troubleshooting

Messages

Continues the list of error messages and their resolutions.

Response of output to errors

Defines how the output reacts to different error conditions.

Repair of Ex-certified devices

Specific safety and procedural guidelines for Ex-certified devices.

Appendix

Description of parameters

Detailed explanations of parameters within the expert menu.

Expert È Output È Current output

Parameters for configuring the current output signal.

Expert È Communication È HART config

Parameters for HART communication configuration.

Expert È Communication È HART output

Parameters for configuring HART protocol output.

Expert È Application È Totalizer 1 (Deltabar M)

Parameters for configuring Totalizer 1 for Deltabar M.

Expert È Application È Totalizer 2 (Deltabar M)

Parameters for configuring Totalizer 2 for Deltabar M.

Pos. zero adjust (007)

Adjusting zero point for Deltabar M and relative pressure sensors.

Calib. offset (192) / (008)

Adjusting calibration offset for absolute pressure sensors.

Expert È Communication È HART input

Parameters for configuring HART protocol input.