EasyManua.ls Logo

Endress+Hauser Micropilot FMR53 - Page 26

Endress+Hauser Micropilot FMR53
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Micropilot FMR53, FMR54
26 Endress+Hauser
Connection examples for the switch output
For HART devices, the switch output is available as an option.
3+
+
-
4-
R
i
A0015909
 14 Connection of a relay
3+
2
1
+
4-
R
i
A0015910
 15 Connection to a digital input
1 Pull-up resistor
2 Digital input
For optimum interference immunity we recommend to connect an external resistor (internal
resistance of the relay or pull-up resistor) of < 1 000 Ω.

Other manuals for Endress+Hauser Micropilot FMR53

Related product manuals