Micropilot FMR53, FMR54
Endress+Hauser 35
Installation
Installation conditions Orientation
A
1 2 3
A0016882
Recommended distance A wall - nozzle outer edge: ~ 1/6 of the vessel diameter. However, the
device must not under any circumstances be mounted closer than 30 cm (11.8 in) to the tank wall.
Not in the center (2) as interference can cause signal loss.
Not above the filling curtain (3).
The use of a weather protection cover (1) is recommended to protect the transmitter from direct
sunlight or rain.