EasyManua.ls Logo

Endress+Hauser Micropilot FMR53 - Page 42

Endress+Hauser Micropilot FMR53
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Micropilot FMR53, FMR54
42 Endress+Hauser
A
B
90°
90°
90°
90°
90°
90°
90°
90°
90°
90°
A0018974
Depending on the device version the marking may be a circle or two parallel lines.
Information concerning nozzles
The horn antenna should project out of the nozzle; select the version with the antenna extension
100 to 400 mm (4 to 16 in) if necessary (accessory).
H
1
øD
A0016822
 20 Nozzle height and diameter for horn antenna
1 Mounting nozzle
Antenna ØD Maximum nozzle height H
max
(Antenna without antenna extension)
150mm/6" 146 mm (5.75 in) 185 mm (7.28 in)
200mm/8" 191 mm (7.52 in) 268 mm (10.6 in)
250mm/10" 241 mm (9.49 in) 360 mm (14.2 in)
Antenna versions < 150mm/6" are not suitable for free-space installation in the tank. They
should only be used in bypasses or stilling wells.
Measurement from the outside through plastic walls
Dielectric constant of the medium: ε
r
> 10
If possible use an antenna 250 mm (10 in).
The distance from the tip of the antenna to the tank should be approx. 100 mm (4 in).