EasyManua.ls Logo

Endress+Hauser Micropilot FMR53 - Page 47

Endress+Hauser Micropilot FMR53
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Micropilot FMR53, FMR54
Endress+Hauser 47
Example for the design of a bypass
B
5
A-A
1
100%
0%
A A
200 (7.87)
200 (7.87)
200 (7.87)
200 (7.87)
4
4
2
C
3
3
1 (0.04)
A0019010
A Micropilot FMR50/FMR51/FMR52/FMR54: horn 80 mm (3")
B Full bore ball valve
C Minimum distance to upper connecting pipe: 400 mm (15.7 in)
1 Marking for axial alignment
2 e.g. welding neck flange DIN2633
3 Diameter of connecting pipes as small as possible
4 Do not weld through the pipe wall; the inside of the pipe must remain smooth.
5 Opening diameter of ball valve must always correspond to the pipe diameter. Avoid edges and constrictions.

Other manuals for Endress+Hauser Micropilot FMR53