EasyManua.ls Logo

Endress+Hauser NRF81 - Page 116

Endress+Hauser NRF81
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating menu Tankside Monitor NRF81
116 Endress+Hauser
Additional information
Read access Operator
Write access -
15.2.3 "Density" submenu
Navigation  Operation → Density
Observed density
Navigation  Operation → Density → Observed density
Description Calculated density of the product.
Additional information
Read access Operator
Write access -
This value is calculated from different measured variables depending on the selected
calculation method →  188.
Vapor density
Navigation  Operation → Density → Vapor density
Description Defines the density of the gas phase in the tank.
User entry 0.0 to 500.0 kg/m³
Factory setting 1.2 kg/m³
Additional information
Read access Operator
Write access Maintenance
Air density
Navigation  Operation → Density → Air density
Description Defines the density of the air surrounding the tank.
User entry 0.0 to 500.0 kg/m³

Table of Contents