Proline Promass 80 Hardware settings
Endress+Hauser 17
PROFIBUS
A0007552
Device address range: 0 to 126
Factory setting: 126
a. Miniature switches for the device address
(example shown:
1+16+32 = device address 49)
b. Miniature switches for the address mode
(method of addressing):
OFF (factory setting) = software addressing via local
operation/operating program
ON = hardware addressing via miniature switches
c. Miniature switch not assigned.