33
5.4 Group Sensor Setup
Picklist SENSOR SETUP:
•SETUP
LIQUID
PIPE DATA
LINER
CONFIG. CHANEL
POS. SENSOR
QUIT
SETUP: LIQUID TE
MPERATURE SOUND VEL. LIQUID 
PIPE MATERIAL SOUND VEL.PIPE CIRCUMFERENCE 
PIPE DIAMETER WALL THICKNESS LINER MATERIAL 
SOUND VEL. LINER LINER THICKNESS SENSOR TYPE 
SENSOR CONFIG. CABLE LENGTH POS.SENSOR/WIRE
LENGTH SENSOR DISTANCE
LIQUID: LIQUID TEMPERATURE SOUND VEL. LIQUID
PIPE DATA: PIPE MATERIAL SOUND VEL.PIPE CIRCUMFERENCE 
PIPE DIAMETER WALL THICKNESS
LINER: LINER MATERIAL SOUND VEL. LINER LINER THICKNESS
CONFIG. CHANNEL:SENSOR TYPE SENSOR CONFIG. CABLE LENGTH
POS.SENSOR:POS.SENSOR/WIRE LENGTH SENSOR DISTANCE
The following information is required for a successful setup:
Sound velocity of the liquid
•Operating temperature
Pipe circumference or pipe outer diameter
Sound velocity of the pipe material
Wall thickness
Sound velocity of the lining material (if present)
Thickness of the lining (if present)
•Sensor type
Sensor arrangement (direct or reflection mode)
Length of the sensor cable
5.5 Troubleshooting
A complete description of all the error messages is provided in the Operating Instructions on the
CD-ROM.
!
Note!
The output signals (e.g. pulse, frequency) of the measuring device must correspond to the
higher-order controller.