ENFORCER Voice Dialer
SECO-LARM U.S.A., Inc. 7
Programming the Voice Dialer (Continued):
Setting the Auto-Dial Mode
The dialer can be programmed to dial each programmed number once (up to 6 numbers) when an
alarm is triggered, or it can continually dial each number in a loop until the dialer is reset. To set the
dialing mode, in setup mode:
1. Press the UP or DOWN button until you see "03 Dialing
Mode" on the display, or press 03 on the keypad.
2. Press the ENTER button and press 0 or 1 to make your
selection.
0 = Single (default) – The dialer will dial each number once and then stop.
1 = Loop – The dialer will continuously loop, dialing each number until the alarm is disabled.
3. After making your selection, press ENTER to set.
4. When finished, press the ESC button to return to the settings menu to program other functions.
5. Press the ESC button again to exit the setup mode.
NOTE: With either setting, when you receive the call, you can remotely stop the dialing cycle and
return the dialer to standby mode (see Remote Control by Telephone, pgs. 10~11).
Setting the Trigger Level
Each of the inputs (IP1, IP2, IP3, INH), can be set to match the type of input device connected. To
change the trigger level, in the setup mode:
1. Press the UP or DOWN button until you see "04 Trigger
Level" on the display, or press 04 on the keypad.
2. Press the ENTER button. You will see "IP1Trigger Level"
on the display for input 1 and its current setting.
3. Press the DOWN button to select a different input if desired. When the desired input is shown,
press the ENTER button to select.
4. Press the number corresponding to your selection.
0 = H-NO – (High N.O.) N.O. input will trigger the dialer
when the voltage at the input exceeds 3.5VDC (maximum is 15VDC).
1 = H-NC – (High N.C.) N.C. input will trigger the dialer when the voltage at the input
exceeds 3.5VDC (maximum is 15VDC).
2 = L-NO – (Low N.O.) N.O. input will trigger the dialer when the voltage at the input is less
than 1VDC.
3 = L-NC – (Low N.C.) N.C. input will trigger the dialer when the voltage at the input is less
than 1VDC.
5. Press ENTER to set.
6. Press the UP or DOWN button to select another input and repeat the steps above.
7. When finished, press the ESC button to return to the settings menu to program other functions.
8. Press the ESC button again to exit the setup mode.
NOTE: If the "Inhibit" input is not being used, it should be left as Low N.C. (L-NC).
Menu(1-12)
04 Trigger Level
IP1Trigger Level
L-NO
Menu(1-12)
03 Dialing Mode
Select Mode=0
0=Single 1-Loop
IP1(0-3)
L-NO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ENFORCER E-922CPQ and is the answer not in the manual?

ENFORCER E-922CPQ Specifications

General IconGeneral
BrandENFORCER
ModelE-922CPQ
CategoryIntercom System
LanguageEnglish

Related product manuals