■ Error Message (Digital display of temperature controller)
Error message will be displayed if the voltage of the battery is low or in the event of any troubles - (see table below).
To reset the error, reset the power
Error message
※1 The voltage detection position is the terminal block of the refrigerator. (The voltages at the battery and terminal block are different to include the wiring drop.)
※2 No error is displayed if the fan is disconnected during operation. An error will occur at startup when the refrigerator is disconnected while the refrigerator is off.
■ About the battery protection function
This refrigerator has a battery protection function for battery protection.
(The above error code <.>)
If the battery voltage is low, the refrigerator stops as shown in the table on the right.
The refrigerator automatically returns when the battery voltage returns to normal voltage.
(Refer to page 8 for setting method)
At DC12V input Operation automatic return voltage
At DC24V input Operation stop voltage
At DC24V input Operation automatic return voltage
5. TROUBLE SHOOTING
9
9.6V or less
23.1V
25.0V
Battery protection settings
At DC12V input Operation stop voltage
HI
7.9V or less
10.5V
11.5V
9.6V or less
11.5V
12.5V
7.9V or less
21.0V
23.1V
E-5
Internal thermistor inspection
-
-
32.0V≦voltage(※1)≦35.0V (10s continuous)
Voltage(※1)≧45.0V (10s continuous)
E-4
E-8
14
Voltage(※1)≦ 9.6V (10s continuous)
17.0V ≦ voltage(※ 1)≦ 20.4V (10s continuous)
Voltage(※1)≦ 10.6V (10s continuous)
17.0V ≦ voltage(※ 1)≦ 22.5V (10s continuous)
14
SEE
PAGE
no display
The dot <.>
Flashes
Return condition
Battery
Protection
9.6V or more
-
E-9
E-10
ERROR
CODE
Other than
combi type
Combi type
Error code existence
CAUSE
Judgment criteria
SOLUTIONS
E-6
Power reset
Power reset
Power reset
Power reset
Increase ambient temperature or
move to a warmer place.
EVA.Thermistor inspection
EVA.Thermistor inspection
Check battery
E-7
-
Ambient temperature is too low
(Substrate ambient temperature)
Thermistor short or Internal temperature
overheating abnormality
Thermistor disconnection or internal
temperature drop abnormal
Abnormal input DC voltage (too
high)
Internal thermistor short or internal
temperature overheating
Internal thermistor disconnection or
internal temperature drop abnormal
Internal fan motor disconnection
※2, FAN voltage ≦ 1V or less (5s continuous)
LO
Power reset
Power reset
Power reset
Internal thermistor inspection
OFF
Temperature ≦ -40 ℃ (5s continuous)
Abnormal input
DC voltage
Voltage(※1)≦ 7.9V (10s continuous)
Temperature ≧ 75 ℃ (5s continuous)
Temperature ≦ -40 ℃ (5s continuous)
Temperature ≧ 75 ℃ (5s continuous)
OFF
LO
HI
14
14
Inspection of internal fan motor
15
* Operates when the voltage value
continues for 10 seconds
Check battery
-
-
See the table below
(battery protection
settings)
Temperature ≦ -20 ℃ (5s continuous)

Other manuals for Engel MT45F-U1D-P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Engel MT45F-U1D-P and is the answer not in the manual?

Engel MT45F-U1D-P Specifications

General IconGeneral
BrandEngel
ModelMT45F-U1D-P
CategoryRefrigerator
LanguageEnglish

Related product manuals