EasyManuals Logo

Enovation Controls MURPHY PowerCore TEC-10 User Manual

Default Icon
65 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #53 background imageLoading...
Page #53 background image
Software Release: [App: 02.09.10051.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042;
BTL: 02.09.10015.00]
Section 40 53 00-02-0939
2019-06-13
1 = Reserved
Reserved
2 = Reserved
Reserved
3 = Reserved
Reserved
4 = Reserved
Reserved
5 = Reserved
Reserved
6 = Reserved
Reserved
7 = Reserved
Reserved
8 = Reserved
Reserved
9 = Reserved
Reserved
10 = Reserved
Reserved
11 = Reserved
Reserved
12 = Reserved
Reserved
13 = Reserved
Reserved
14 = Reserved
Reserved
15 = Reserved
Reserved
40214
Read Only
Controller State Timer
Seconds
40215
Read Only
Target Engine Speed from Controller
RPM
40216
Read Only
All Purpose Auto Start Function: (Active Function: Numeral
Indicated)
Numerals
0 = Single Contact
1 = Local Start Button
2 = Two Contact Maintained
3 = Pressure Transducer
4 = Level Transducer
40217
Read & Write
Pressure Maintain Deadband (Auto)
kPa
40218
Read & Write
System Level Maintain Deadband (Auto)
Feet
40219
Reserved
Reserved
Reserved
40220
Read & Write
Ambient Temperature Engine Start (Auto)
Celsius
40221
Read & Write
Ambient Temperature Engine Stop (Auto)
Celsius
40222
Reserved
Reserved
Reserved
40223
Reserved
Reserved
Reserved
40224
Read & Write
Minimum Engine Speed Setpoint
RPM
40225
Read Only
Service Reminder - Air Filter Life
Hours
40226
Read Only
Service Reminder - Air Filter Life Remaining
Hours
40227
Read Only
Service Reminder - Battery Life
Hours
40228
Read Only
Service Reminder - Battery Life Remaining
Hours
40229
Read Only
Service Reminder - Belt Life
Hours
40230
Read Only
Service Reminder - Belt Life Remaining
Hours
40231
Read Only
Service Reminder - Fuel Filter Life
Hours
40232
Read Only
Service Reminder - Fuel Filter Life Remaining
Hours
40233
Read Only
Service Reminder - Oil Filter Life
Hours
40234
Read Only
Service Reminder - Oil Filter Life Remaining
Hours
40235
Read Only
Service Reminder - Oil Life
Hours
40236
Read Only
Service Reminder - Oil Life Remaining
Hours
40237
Read Only
Service Reminder - Overhaul Life
Hours
40238
Read Only
Service Reminder - Overhaul Life Remaining
Hours
40239
Read Only
Actual Fuel Level
Percent
40240
Read & Write
Modbus EEPROM Values Save (Save = 1)
(0 or 1)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enovation Controls MURPHY PowerCore TEC-10 and is the answer not in the manual?

Enovation Controls MURPHY PowerCore TEC-10 Specifications

General IconGeneral
BrandEnovation Controls
ModelMURPHY PowerCore TEC-10
CategoryController
LanguageEnglish

Related product manuals