AC Battery Installation
© 2016 Enphase Energy Inc. 141-00036 Rev 01
19
Battery LED is Solid Amber
Check the temperature in the room and increase cooling and/or ventilation as required to meet
temperature requirements. The AC Battery requires an ambient temperature between -4° F (-20° C)
and 113° F (45° C), and where relative humidity is between 5 and 95 percent.
Check that the front, top, and sides of the AC Battery array have at least one foot of unobstructed
clearance.
NOTE: If the AC Battery registers a high temperature event, it responds by reducing
operation to correct internal temperature.
System Alert: “AC Battery(ies) with Critical Temperature
Check the temperature in the room and increase cooling and/or ventilation as required to meet
temperature requirements. The AC Battery requires an ambient temperature between -4° F (-20° C)
and 113° F (45° C), and where relative humidity is between 5 and 95 percent.
Check that the front, top, and sides of the AC Battery array have at least one foot of unobstructed
clearance.
NOTE: If the AC Battery registers a high temperature event, it responds by reducing
operation to correct internal temperature.

Other manuals for enphase AC Battery

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the enphase AC Battery and is the answer not in the manual?

enphase AC Battery Specifications

General IconGeneral
Brandenphase
ModelAC Battery
CategoryInverter
LanguageEnglish

Related product manuals