15. Testing instructions for the electric protective device
Press the TEST button.
The rocker turns to 0 position.
Turn the rocker back to I position.
If a fault occurs, contact an electrician.
16. Troubleshooting
Charging station is o, no lights on
Issue Corrective action
Mains voltage does not exist in supply con-
nectors (L1, L2, L3).
Make sure that the supply conductors are properly con-
nected. Make sure that there is power available.
The circuit breaker F0 is o. Turn the F0 on.
The PWR LED indicator on the controller is
not on.
Make sure that power supply to the controller is available.
Charging cable is locked in Mode 3 socket outlet
Issue Corrective action
Unexpected fault has occurred while pow-
er is on.
Turn o the power from the F0 and pull the charging
cable out from the socket.
Power is o. Switch Mode 3 lock into open position.
Conguration via web browser
Issue Corrective action
PC does not recognize micro USB plug and
connection to the controller cannot be es-
tablished via web browser.
Make sure from Windows operating system settings via
“Device Manager that RNDIS network adapter is avail-
able. If not, contact your local IT support.

Related product manuals