EasyManua.ls Logo

Enterasys Matrix-V V2H124-24 - Application Notes

Enterasys Matrix-V V2H124-24
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Network Planning
2-6
2
Application Notes
1. Full-duplex operation only applies to point-to-point access (such as when a
switch is attached to a workstation, server or another switch). When the switch
is connected to a hub, both devices must operate in half-duplex mode.
2. Avoid using flow control on a port connected to a hub unless it is actually
required to solve a problem. Otherwise back pressure jamming signals may
degrade overall performance for the segment attached to the hub.
3. As a general rule the length of fiber optic cable for a single switched link should
not exceed:
1000BASE-SX/LX: 550 m (1805 ft) for multimode fiber or 5 km (3.2 miles) for
single-mode fiber.
100BASE-FX: 2 km (1.24 miles) for multimode fiber or 20 km (12.43 miles) for
single-mode fiber.
However, power budget constraints must also be considered when calculating
the maximum cable length for your specific environment.

Table of Contents

Other manuals for Enterasys Matrix-V V2H124-24

Related product manuals