12 Issue 2009-06-17 1005274-EMEI-2.0
Safety accessories
Even though the EMSL is installed to comply with all applicable safety regulations, it is pos-
sible to enhance safety/comfort with the following add-ons (please contact your local
EntreMatic company for detailed description).
Combined motion and presence sensors
Separate presence sensors
General accessories
Your EMSL can be further improved with the following add-ons (please contact your local
EntreMatic company for detailed description).
Cover
Made in clear anodized aluminium as standard.
Motion sensors, see separate manuals or installation drawings.
–Programme selectors (see page 6)
Electrical locks
Locked with power, locked without power or bistable lock.
Manual unlocking device
For manual unlocking the electrical lock.
Micro switch kit
For indication of door and lock position.
Electrical emergency unit
Used if a door is required to be closed or opened by means of a rechargeable battery unit
and remain in this position in the event of power failure. Every 3.5 hours the following
opening impulse generates an emergency opening test if monitoring of the emergency
unit is selected. If there is no opening impulse within an additional time, specified by the
authorities, the operator control unit generates the opening impulse itself.
If the battery opens the door within the limited time the test is successful and the door
resumes the function set by the programme selector.
Note! The test is never performed in programme selector setting “Open”. In setting “Off”
it can be selected. The test is always performed after a Reset and after changing program
selection, from a position where a test is not done to a position where the test is a
demand.
Emergency closing with repeated closing
If the door is opened by hand after an electrical emergency closing, it will close again.
Mechanical emergency unit
Used if a door is required to be opened and remain opened by means of an elastic cord in
the event of power failure. Every 3.5 hours the following opening impulse generates an
emergency opening test if monitoring of the emergency unit is selected. If there is no
opening impulse within an additional time, specified by the authorities, the operator con-
trol unit generates the opening impulse itself. If the elastic cord opens the door within the
limited time the test is successful and the door resumes the function set by the pro-
gramme selector.
Note! The test is never performed in programme selector setting “Open”. In setting “Off”
it can be selected. The test is always performed after a Reset and after changing program