1005274-EMEI-2.0 Issue 2009-06-17 9
Regular safety checks
To help you fulfil the requirements in the European Directives and to avoid malfunction and
risk for injuries, we have made the following checklist.
= Contact your EntreMatic representative. For contact information, see last page.
= Take appropriate measures.
Action
If problem
occurs
Activate your operator and visually check, fastening of
operator and cover
•cables
programme selector(s)
door and glass (stability)
Also inspect your operator and check visually for
condition of door seals and weather stripping
condition of glazing rubbers
finger protection
proper operation; closes slowly and smoothly
Set the programme selector to OFF and check that the operator and electrome-
chanical lock (if fitted) work together. Also check that the lock really secures
the door .
Activate the manual activation units , if any, and walk towards the door.
Check that the door has opened appropriately while you pass the entrance/exit.
Then proceed with the automatic activation units in the same way
Check the safety sensors if any. If you are unsure of which type of sensor
you have, please contact your EntreMatic representative.
Escape
doors
By law, these tests must be performed
regularly by trained personnel.
If the operator is equipped with break-out system, set the
programme selector to Auto mode. Push the door manu-
ally while in the escape direction to ensure that nothing
prevents the door from being open.
Also ensure that the escape route is free for use. After
the test, restore the door(s) to their normal mode of oper-
ation.
If the operator is equipped with automatic opening sys-
tem, shut off the power and the door should open and
remain open. Restore power and the door should close.
Fire doors Let the door close after an impulse ensuring nothing pre-
vents the door from closing and locking (if regulations
require it).
Do not use if repair or adjustment is necessary.
Disconnect supply when cleaning or other maintenance is to be carried out.
12
1
2
3
4
5
6
7
8
9
10
11

Related product manuals