HORIZONTAL INSTALLATION:
STEP 1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the way
when the venting system is attached. If this is the case, you may want to adjust the location of the
appliance.
STEP 2. Direct vent pipe and ttings are designed with special twist-lock connections. Assemble the desired
combination of black pipe and elbows to the appliance adapter with pipe seams oriented towards the wall
or oor, as much out of view as possible.
Place a bead of Mil-Pac on the
outer edge of the inner exhaust
pipe (non-ared end). Place a bead
of high temperature silicone on the
male edge of the outer pipe. Push
the pipe sections completely together,
then twist-lock one section clockwise
approximately turn, until the two
sections are fully locked. The female
locking lugs will not be visible from the
outside, on black pipe. They may be
located by examining the inside of the
female ends as shown in Figure 7.
Notes:
(1) Twist-lock procedure: four indentations, located on the female end of the pipes and ttings, are designed to
slide straight onto the male ends of adjacent pipes and ttings, by orienting the four pipe indentations so they
match and slide into the four entry slots on the male end.
(2) Horizontal runs of vent pipe must be supported every three feet. Wall straps are available for this purpose, also
when running horizontal pipe minimum clearances to combustibles must be maintained; 2 inches (5.1 cm) at
top, 1 inches (3.8 cm) at sides, 1 inches (3.8 cm) at bottom.
STEP 3. With the pipe attached to the stove in the correct location, mark the wall for a 10” (25.4 cm) x 10” (25.4
cm) square hole. The center of the square hole should match the centerline of the horizontal pipe. Cut
and frame the 10” (25.4 cm) x 10” (25.4 cm) hole in the exterior wall where the vent will be terminated.
Refer to Figure 8. If the wall being penetrated is constructed of non-combustible material i.e. masonry or
concrete, a 7 inches (17.8 cm) hole is acceptable.
9
Sealant
Female
Locking
Lugs
Male
Locking
Lugs
Figure 7: Twist-Lock Connection
Initial Installation
QUALIFIED INSTALLERS ONLY
Woodscrews
Wall Thimble
Strap
Sheet metal
screws
Fold strap
here
1
1
/4"
(3.2cm)
Figure 9: Installing Decorative Wall Thimble.




Figure 8: Wall Framing Hole for
Horizontal Installation.