Measurement Principle | Electrochemical analysis |
---|---|
Sensor | Electrochemical |
Resolution | 0.01 mg/L |
Operating Temperature | -5°C to +50°C |
Storage Temperature | -20°C to +60°C |
Power Supply | 2 x AA batteries |
Measurement Range | 0.00 to 2.50 mg/L (0.00 to 5.00 ‰ or 0.00 to 0.50 %BAC) |
Importance of following the manual for safe and efficient operation of the device.
Explains the meaning of warning and attention symbols used in the manual.
Details mandatory six-monthly calibration and expert maintenance for device accuracy.
Prohibits device operation in explosion hazardous areas for safety.
Instructions for proper disposal of defective devices and batteries.
Describes the AlcoQuant 6020 breathalyser, its components, and key functions.
Explains the device's use for fast and accurate alcohol level determination in breath.
Illustrates and labels the physical controls and ports of the AlcoQuant 6020.
Explains the meaning of various symbols displayed on the AlcoQuant 6020.
Details how to prepare a new AlcoQuant 6020 for its first use.
Outlines checks required before recommissioning a previously used device.
Step-by-step instructions for powering on the AlcoQuant 6020 and its self-test.
Specifies conditions for the test person, like avoiding alcohol and smoke before testing.
Guides through inserting the mouthpiece and the sample collection process.
Explains how to print measurement reports using an optional printer.
Details how to prepare for subsequent measurements after a test.
Instructions for properly powering down the AlcoQuant 6020.
Describes the "Blow failure" error and how to resolve it.
Explains the "Flat battery" error and the required action.
Details how the device logs and stores measurement results.
Explains what happens when the data memory is full and how to acknowledge it.
Shows how to navigate the main menu to access auxiliary functions.
Describes the purpose and procedure for passive measurement mode.
How to retrieve and display the most recent measurement results.
Navigates to the main settings menu for device configuration.
Instructions for adjusting the device's internal time.
How to adjust the display contrast for better readability.
Explains how to change the measurement units (e.g., %o, mg/L).
Describes how to enable or disable audible feedback for key presses.
Instructions for selecting the device's display language.
How to display the total operating hours and number of measurements performed.
Guidelines for cleaning the device safely and effectively.
Importance of keeping electrical contacts clean and dry for device longevity.
Explains how the device indicates the current battery charge status.
Step-by-step guide on how to open the compartment and replace batteries.
Details the required frequency for calibration and professional servicing.
Describes the "Blow failure" error and its resolution.
Explains errors related to the signal generator (yellow LED).
Covers errors related to LEDs and date/time determination.
Details errors from temperature, pump, memory, and sensor faults (red LED).
Explains errors related to incorrect calibration dates or status.
Lists key technical data like measurement range, accuracy, and dimensions.
Details operational modes, power-saving, display, and data memory capabilities.
Information on ordering the complete AlcoQuant 6020 device and its standard accessories.
Lists items required for calibration, maintenance, and repair.
Outlines the terms, duration, and limitations of the product warranty.
Provides the address and instructions for sending devices for repair.