15
Battery Voltage, Current, Temperature
Battery type
Load
Load ON
Load OFF
Current/Consumed energy/Load mode
2 Error codes
Status
Icon
Instruction
Battery
over-discharged
Battery level shows empty, battery frame
blink, fault icon blink
Battery over voltage
Battery level shows full, battery frame
blink, fault icon blink
Battery overheating
Battery level shows current value, battery
frame blink, fault icon blink
Load failure
Overload
, Load short circuit
When the load current reaches1.02-1.05 times, 1.05-1.25 times, 1.25-1.35 times, and 1.35-1.5 times
more than the rated value, the controller will automatically turn off the loads in 50 seconds, 30
seconds,10 seconds, and 2 seconds respectively.
3 Browse interface
Press the SELECT button to cycle display the following interfaces.