16
3.3 Setting
1) Clear the generated energy
Step 1: Press the ENTER button and hold 5s under the PV-generated energy interface, and the value
will be flashing.
Step 2: Press the ENTER button to clear the generated energy.
2) Switch the battery temperature unit
Press the button and hold 5s under the battery temperature interface.
3) Battery type
Support battery types
1
Battery
Sealed(default)
Gel
Flooded
2
Lithium
battery
LiFePO4(4S/ 8S)
Li(NiCoMn)O2 (3S/6S/7S)
3
User
Set the battery type via the LCD
Operation:
Step1: Press the SELECT button to browse the battery voltage interface.
Step2: Press and hold the ENTER button until the battery-type interface flashes.
Step3: Press the SELECT button to change the battery type, shown as below: