performance.
The recommended wire is selected for the battery according to the conditions
that its terminals are not connected to any additional inverter.
Risk of explosion! Never install the controller in a sealed enclose with flooded
batteries! Do not install the controller in a confined area where battery gas
can accumulate.
Risk of electric shock! When wiring the PV modules, the PV array may
generate a high open-circuit voltage. Turn off the breaker or fuse firstly, and
be careful when wiring.
The controller requires at least 150mm of clearance above and below for proper
airflow. Ventilation is highly recommended if mounted in an enclosure.
Installation procedures:
Step 1: Determine the installation location and heat-dissipation space
Figure2-1 Mounting
Step 2:Connect the system in the order of battery -- load --PV array following Figure 2-2,"
Schematic Wiring Diagram," and disconnect the system in the reverse order.