25
Battery over
voltage
Check whether the battery voltage is
higher than OVD (over voltage
disconnect voltage) and disconnect the
PV array connection.
Battery over
discharged
When the battery voltage is restored to
or above LVR (low voltage reconnect
voltage), the load will recover.
Take other ways to recharge the
battery.
Battery
overheating
While the temperature decline to be
below 55 ºC, the controller will resume.
Overload
1. Load off
2
Please reduce the number of electric
devices.
Restart the controller or press the
button to clear faults.
Load short-circuit
Check carefully loads connection,
clear the fault,
Restart the controller or press the
button to clear faults.
When the load current goes higher than 1.02-1.05 times, 1.05-1.25 times, 1.25-1.35 times, and
1.35-1.5 times the rated value, the controller may automatically turn offloads in 50 seconds, 30
seconds,10 seconds, and 2 seconds respectively.
Battery frame blink,
fault icon blink
Battery frame blink,
fault icon blink
Battery frame blink,
fault icon blink
Load and fault
icon blink