10
heating. And it automatic restarts when the temperature recovers to
the normal level.
Others
Saving Mode
When the switch is on “Saving” side, the inverter will enter into the
Saving Mode. It will shut off the output if the loads value is less than
50VA. Then restart and detect the power of the load again after 10s.
If the load is more than 50VA, the inverter will turn on the output.
Otherwise it will shut off output again. It cycles like this. So please
don‟t use the saving mode if the load is smaller than 50VA.
Mode Switch
The output mode can be changed by the mode switch. When the
switch No.1 is on the ON side, the inverter will enter into the saving
Mode. This mode can be switched online.
When the switch No.2 is on the ON side, the output voltage is
230Vac, otherwise is 220Vac.When the switch No.3 is on the ON
side, the output frequency is 60Hzotherwise is 50Hz. Both the
output frequency and the output voltage change availability after
restart the inverter.

Related product manuals