EasyManua.ls Logo

Epever TRIRON4210N - User Manual

Epever TRIRON4210N
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
MPPT Solar Charge Controller
User Manual
Models:
TRIRON1206N/TRIRON1210N
TRIRON2206N/TRIRON2210N
TRIRON3210N/TRIRON3215N
TRIRON4210N/TRIRON4215N

Questions and Answers

  • T
    tina68Aug 6, 2025
    What to do if the Epever TRIRON4210N Controller is not working even when the wire connection is correct?
    • D
      Denise GardnerAug 6, 2025
      If your Epever Controller isn't working despite correct wire connections, the battery voltage may be too low. Ensure the battery voltage is at least 9V to activate the controller.
  • M
    martinezjonAug 21, 2025
    Why is the charging LED indicator off on my Epever TRIRON4210N Controller during the day with proper sunshine on the PV modules?
    • C
      Catherine BoydAug 21, 2025
      The charging LED indicator might be off because of a PV array disconnection. Confirm that the PV and battery wire connections are correct and tight.

Summary

Important Safety Instructions

General Safety Information

Read all instructions and warnings before installation; avoid disassembly.

General Information

Overview

Introduction to TRIRON series controllers, modular design, and MPPT technology.

Installation

Attentions

Safety precautions for battery handling, ventilation, and wiring.

PV Array Requirements

Guidelines for PV module connection, voltage, and power.

Wire Size

Recommended wire sizes for PV array, battery, and load connections.

Parameters Setting

Others

Protection

Details on PV and battery protection functions against overcurrent, short circuit, etc.

Troubleshooting

Common faults, possible reasons, and troubleshooting steps for controller issues.

Technical Specifications

Epever TRIRON4210N Specifications

General IconGeneral
ModelTRIRON4210N
System Voltage12V/24V Auto
Rated Charge Current40A
Rated Discharge Current20A
Max PV Input Voltage100V
Max PV Input Power520W (12V) / 1040W (24V)
Efficiency≤98%
Temperature Compensation-3mV/°C/2V(Default)
TypeMPPT
CommunicationRS485
Battery TypeSealed, Gel, Flooded, User
GroundingNegative Ground
Charge AlgorithmMPPT
ProtectionReverse Polarity
Operating Temperature-25°C to 55°C