XTRA N Series
——MPPT Solar Charge Controller
User Manual
Models:
XTRA1206N/XTRA2206N
XTRA1210N/XTRA2210N
XTRA3210N/XTRA4210N
XTRA3215N/XTRA4215N
XTRA3415N/XTRA4415N

Questions and Answers

  • R
    ronnie82Aug 19, 2025
    How to fix the charging LED indicator off during daytime when sunshine falls on PV modules properly on my Epever Controller?
    • N
      Nathaniel WalshAug 19, 2025
      If the charging LED indicator is off during the daytime when sunshine falls on PV modules properly, confirm that the PV wire connections are correct and tight.
  • O
    ovaughnAug 21, 2025
    What happens if my Epever XTRA N Controller experiences battery overvoltage?
    • R
      Robert MuellerAug 21, 2025
      When the battery voltage reaches the over-voltage disconnect voltage on the Epever Controller, the battery charging will automatically stop. This prevents damage to the battery that could be caused by over-charging.
  • M
    Michael BarrettAug 23, 2025
    What happens if my Epever XTRA N Controller's lithium battery gets too cold?
    • M
      Mark RhodesAug 23, 2025
      If the temperature detected by the optional temperature sensor is below the low temperature threshold (LTPT) on your Epever Controller, the controller will automatically stop charging and discharging.
  • L
    lisa64Aug 26, 2025
    What happens if the battery is too low on my Epever Controller?
    • D
      Debbie HernandezAug 27, 2025
      When the battery voltage reaches the undervoltage disconnection voltage, the battery discharge is automatically stopped to avoid damage to the battery caused by excessive discharge.
  • C
    chelsea23Aug 28, 2025
    What happens if I reverse the battery polarity on my Epever XTRA N?
    • N
      Nicholas StephensAug 28, 2025
      The Epever Controller is fully protected against reversed battery polarity. To restore normal operation, switch to the correct polarity.
  • K
    kimberlyhallAug 30, 2025
    Why is my Epever Controller showing PV excess current or power?
    • T
      toddpierceAug 30, 2025
      If the charging current or power of the PV panels exceeds the rated current or power of the Epever Controller, it will be charged at the rated current or power.
  • A
    alicia46Sep 1, 2025
    What happens if I reverse the PV polarity on my Epever XTRA N?
    • D
      dthompsonSep 1, 2025
      If the PV system is connected to the Epever Controller in reverse, the controller may not be damaged and can continue to operate normally after the polarity is correctly connected.
  • B
    Brenda SmithSep 3, 2025
    What to do if the Epever XTRA N Controller load has no output and the load/fault icon is blinking?
    • S
      Sharon WhiteSep 3, 2025
      If the load is not outputting and the load/fault icon is blinking on your Epever Controller, it indicates a load overload. Reduce the number of connected electrical devices, restart the controller, and wait for one night-day cycle (night time>3 hours).
  • C
    Cory GarciaSep 5, 2025
    Why is the load and fault icon blinking on my Epever XTRA N?
    • M
      Meghan WoodardSep 5, 2025
      The blinking load and fault icon on your Epever Controller indicates a load short circuit. Carefully check the load connections, correct the fault, restart the controller, and wait for one night-day cycle (night time>3 hours).
  • Z
    zshepherdSep 7, 2025
    What does it mean when the PV/BATT(orange)/Battery capacity level indicator is fast flashing on my Epever XTRA N?
    • M
      Michael SingletonSep 7, 2025
      A fast flashing PV/BATT(orange)/Battery capacity level indicator on your Epever Controller signifies that the controller is overheating. The controller will automatically cut off input and output circuits when the heat sink temperature exceeds 85°C. It will resume working when the temperature drops below 75°C.

Summary

Installation Instructions

General Installation Notes

Provides essential safety and general notes for installing the solar charge controller.

PV Array Requirements

Specifies requirements for PV array configuration.

Wire Size Recommendations

Details recommended wire sizes for PV, battery, and load connections.

Control Parameters and Settings

Protections, Troubleshooting, and Maintenance

Controller Protection Mechanisms

Details various protection mechanisms like over-current, short-circuit, and overheating.

Fault Diagnosis and Resolution

Provides solutions for common faults related to PV array, battery voltage, and load.

Technical Specifications

Epever XTRA N Series Specifications

General IconGeneral
Efficiency≤98%
Temperature Compensation-3mV/°C/2V (Default)
CommunicationRS485
Battery TypeSealed, Gel, Flooded
ProtectionPV Reverse Polarity