MPPT Solar Charge Controller
User Manual
Models:
XTRA1206N/XTRA2206N
XTRA1210N/XTRA2210N
XTRA3210N/XTRA4210N
XTRA3215N/XTRA4215N
XTRA3415N/XTRA4415N

Questions and Answers

  • M
    Matthew JonesSep 23, 2025
    Why is my Epever Controller not working even though the wire connections are correct?
    • C
      Christopher KennedySep 23, 2025
      If your Epever Controller is not working despite correct wiring, the battery voltage may be too low (lower than 8V). Check the battery voltage and ensure it is at least 8V to activate the controller.
  • M
    Michael AndersonAug 23, 2025
    How to fix the charging LED indicator off during daytime when sunshine falls on PV modules properly on my Epever XTRA2206N?
    • K
      Kirk WebbAug 23, 2025
      If the charging LED indicator is off during the daytime when sunshine falls on PV modules properly, confirm that the PV wire connections are correct and tight.
  • T
    Toni MasonAug 25, 2025
    What to do if my Epever XTRA2206N Controller shows Load Overload?
    • S
      Sharon KellerAug 26, 2025
      If your Epever Controller indicates a Load Overload, try reducing the number of connected electrical devices. Then, restart the controller and wait for a complete night-day cycle (with nighttime lasting more than 3 hours).
  • S
    Steven HolmesAug 26, 2025
    What to do if my Epever XTRA2206N Controller indicates a Load Short Circuit?
    • P
      Patricia WilliamsAug 27, 2025
      If your Epever Controller displays a Load Short Circuit error, carefully inspect the load connections and fix any faults. After correcting the issue, restart the controller and allow it to cycle through one complete night-day period (with nighttime exceeding 3 hours).
  • T
    Tanya WilsonAug 27, 2025
    What happens if my Epever Controller is overheating?
    • M
      Matthew MolinaAug 27, 2025
      If the Epever Controller's heat sink temperature exceeds 85 degrees Celsius, it will automatically cut off the input and output circuits. Normal operation will resume once the temperature drops below 75 degrees Celsius.
  • F
    freemanzacharySep 15, 2025
    What does it mean when the PV/BATT(orange)/Battery capacity level indicator is fast flashing on my Epever Controller?
    • R
      Rachel HansenSep 15, 2025
      A fast flashing PV/BATT(orange)/Battery capacity level indicator on your Epever Controller signifies that the controller is overheating. The controller will automatically cut off input and output circuits when the heat sink temperature exceeds 85°C. It will resume working when the temperature drops below 75°C.
  • U
    ukiddSep 12, 2025
    What to do if the Epever XTRA2206N Controller load has no output and the load/fault icon is blinking?
    • D
      david01Sep 12, 2025
      If the load is not outputting and the load/fault icon is blinking on your Epever Controller, it indicates a load overload. Reduce the number of connected electrical devices, restart the controller, and wait for one night-day cycle (night time>3 hours).
  • T
    Tracy DavisSep 14, 2025
    Why is the load and fault icon blinking on my Epever Controller?
    • M
      Marc TaylorSep 14, 2025
      The blinking load and fault icon on your Epever Controller indicates a load short circuit. Carefully check the load connections, correct the fault, restart the controller, and wait for one night-day cycle (night time>3 hours).
  • C
    christianobrienSep 5, 2025
    What does it mean when the charging indicator is green fast flashing on my Epever XTRA2206N Controller?
    • D
      Dr. Melissa SchmidtSep 5, 2025
      If the charging indicator on your Epever Controller is flashing green rapidly, it signifies a battery over voltage. Check if the battery voltage is higher than OVD (over voltage disconnect voltage), and disconnect the PV.
  • D
    diazkarenSep 2, 2025
    What to do if the load has no output on my Epever Controller?
    • L
      Laura WilsonSep 2, 2025
      If the load has no output on your Epever Controller, it's likely due to a load overload. Reduce the number of electrical devices connected and restart the controller.

Summary

Important Safety Instructions

General Safety Information

Key safety guidelines for installation and operation.

1 General Information

2 Installation

2.4 Mounting

3 Display units

4 Parameters Setting

4.1 Battery parameters

Configuration options for various battery types and settings.

4.2 Load working modes

5 Others

5.1 Protection

Details various protection mechanisms of the controller against faults.

5.2 Troubleshooting

5.3 Maintenance

6 Technical Specifications

Epever XTRA2206N Specifications

General IconGeneral
ModelXTRA2206N
TypeSolar Charge Controller
Rated Voltage12V/24V Auto
Rated Charge Current20A
Rated Load Current20A
Max PV Input Voltage100V
Efficiency≤98%
Charge Circuit Voltage Drop≤0.26V
Discharge Circuit Voltage Drop≤0.15V
Altitude≤3000 m
CoolingNatural Cooling
Temperature Compensation-3mV/℃/2V(Default)
CommunicationRS485
Battery TypeGel / Flooded / User
GroundingNegative
ProtectionOverload, Short circuit, Reverse polarity
Operating Temperature-25°C to +55°C
Storage Temperature-30°C to +70°C
Max PV Input Power260W(12V) / 520W(24V)
Humidity5% to 95% (non-condensing)