6.2 Troubleshooting
Charging LED indicator off during daytime when sunshine falls on solar
modules properly.
Probable Cause:Solar modules disconnected.
Solution:Confirm that PV and battery wire connections are correct and tight.
Battery LED indicator red flashing, LCD displaying ‘OVD’.
Probable Cause:Battery voltage is larger than over voltage disconnect voltage (OVD).
Solution:Check if battery voltage too high, and disconnect solar modules.
Fault LED indicator flashing, LCD displaying ‘Current Err’.
Probable Cause:Charging current in three phases is unbalanced.
Solution:Disconnect solar modules and restart the eTracer; if the fault still exists,
please contact the supplier to make maintenance.
Fault LED indicator flashing, LCD displaying ‘Over Current’.
Probable Cause:Charging current is much more than the rating.
Solution:Please check whether solar modules match with nominal parameter of the
controller. When charging current reaches 1.05~1.2 times of the rating, eTracer will
automatically adjust charging current to the rating or below but not stop; when
charging current reaches 1.2 times much more than nominal value, eTracer will
automatically stop charging in 5 seconds and automatically circularly activated so as
to reconnect charging. There is 5 times limit for reconnecting. The delay for each
reconnecting is 1min, 2 mins, 3mins, 4mins, 5mins corresponding.
Fault LED indicator flashing, LCD displaying ‘Over Temp’.
Probable Cause:Heat sinks operational temperature is quite high to 85℃ or above.
Solution:The controller will automatically stop working. When the temperature is
below 75℃, the controller will resume to work.