EPSON Stylus Pro 3800/3800C/3850 Revision A
DISASSEMBLY & ASSEMBLY Disassembly/Assembly Procedure (Group 1) 149
5. Remove the two screws that secure the PUMP, CAP ASSY., and remove the
PUMP, CAP ASSY. upwards.
Two C.B.S. 3 x 6 screws (6 ± 1 kgf.cm)
Figure 4-77. Removing the screws from the PUMP, CAP ASSY.
Figure 4-78. Removing the PUMP, CAP ASSY.
Insert the two positioning holes of the PUMP, CAP ASSY. over the
guide pins on the FRAME ASSY., SUB, RIGHT to secure the
PUMP, CAP ASSY. See Figure 4-77.
A D J U S T M E N T
R E Q U I R E D
Whenever the PUMP, CAP, ASSY., is replaced,
the corresponding adjustments must be carried out.
See Chapter 5 "ADJUSTMENT" (p190).
C.B.S. 3x6
positioning point
Right side of the printer
PUMP, CAP ASSY.
PUMP, CAP ASSY.