EPSON Stylus Pro 3800/3800C/3850 Revision A
ADJUSTMENT Overview 193
5.1.5 Description of Adjustments
The following tables describe the general outline of the adjustments.
Note "*1": AU = Software tool including Adjustment Program
"*2": AT = Jig or Tool for the adjustment (does not include the program tool)
MECHANICAL ADJUSTMENT
STANDARD ADJUSTMENT
Adjustment General Overview
Tool
Page
AU*
1
AT*
2
PF Timing Belt Tension Adjustment Adjusts the tension of the PF Timing Belt to a specified level. --- P. 198
LD Roller Position Adjustment Adjusts the height of the LD Roller to ensure stable paper feeding. --- P. 200
PG Position Adjustment Adjusts the platen gap to the proper amount. ---
P. 201
Adjustment General Overview
Tool
Page
AU*
1
AT*
2
RTC&USB ID Carries out the initialization of the RTC and writes USB ID. --- P. 203
Head Rank ID Writes the Head Rank ID. --- P. 204
Print Head Slant Adjustment (PF) Prints an adjustment pattern to check if the print head is slanted in the PF direction and corrects if slanted.
--- P. 205
Print Head Slant Adjustment (CR) Prints an adjustment pattern to check if the print head is slanted in the CR direction and corrects if slanted. --- P. 207
Initial Ink Charge Flag ON/OFF Sets or clears a flag for initial ink charge as necessary after replacing the main board.
--- P. 211
Parameter Backup Backs up the parameters stored in the NVRAM on the previous board and uploads it to the new board. --- P. 212
Check PG Checks the operation of the APG.
--- P. 214
Initial ink Charge
Performs an initial ink charge.
--- P. 215
Cleaning
Carries out various cleanings.
--- P. 215
Input Serial Number Writes and reads the serial number. --- P. 216
Colorimetric Calibration Tool Adjusts the amount of ink droplets.
P. 217
Install F/W Installs the firmware. --- P. 229
Ink Mark sensor Adjustment for Auto Nozzle Check Checks and adjusts the operation of the ink mark sensor.
--- P. 230
Washing Head And Discharge Ink Carries out head washing and discharging of ink. --- P. 232
Auto Bi-D Adjustment Adjusts the Bi-D automatically.
--- P. 233