Chapter 6
Using the Operator Panel
Resetting to Factory Defaults
After executing Initialize NVM and rebooting the printer, all the menu parameters or data are reset to
their factory default values.
1. Turn off the printer.
2. Open the rear cover.
3. While holding down the button on the operator panel, turn on the printer.
Ensure that the
(Ready) LED and (Error) LED blink. If the LEDs do not blink, turn off the
printer, and then execute step 3 again.
4. Close the rear cover.
The printer starts initializing the Non-Volatile Memory (NVM).
Important:
Never attempt to turn off the printer. The printer will cease to function.
The printer restarts automatically to apply the settings.
Understanding the Operator Panel Lights
The operator panel lights mean different things, depending on their sequence. Umber and green lights
that are off, on, or blinking indicate printer conditions.
LED Off On Fast Blink Slow Blink
1 Error
Epson AcuLaser M1400 Series User’s Guide