EasyManuals Logo

Epson G10 Series User Manual

Epson G10 Series
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #70 background imageLoading...
Page #70 background image
Setup & Operation 5. Motion Range
60 G10 / G20 Rev.2
5.1.3 Max. Pulse Range of Joint #3
The 0 (zero) pulse position of Joint #3 is the position where the shaft is at its upper limit.
The pulse value is always negative because Joint #3 always moves lower than the 0 pulse
position.
Upper limit: 0 pulse
Model Joint #3 Stroke Minimum Limit Pulse
G10/G20-**1S* 180 mm
-1946420
G10/G20-**4S* 420 mm
-2270823
G10/G20-**1C* 150 mm
-1622016
G10/G20-**4C* 390 mm
-2108621
)
NOTE
For the Cleanroom-model
(G10/G20-***C*), the motion range set with the Joint #3
mechanical stop cannot be changed.
5.1.4 Max. Pulse Range of Joint #4
The 0 (zero) pulse position of Joint #4 is the position where the flat near the end of the
shaft faces toward the end of Arm #2. With the 0 pulse as a starting point, the
counterclockwise pulse value is defined as the positive (+) and the clockwise pulse value
is defined as the negative (-).
+Y
+X
Clockwise (-value)
Counterclockwise (+value)
G10
0 pulse ±1951517 pulse
G20
0 pulse ±2752512 pulse

Table of Contents